Introduction

The 80 Plus program was introduced a decade ago with the aim of promoting the development of more efficient and environmentally friendly computer PSUs. Since then, it has undoubtedly become one of the favorite subjects of PSU marketing teams. Not long ago, an 80 Plus Bronze certification was more than adequate for a mainstream product, with 80 Plus Gold certifications reserved for premium product ranges. Today, 80 Plus Gold certified units can be found retailing at very reasonable prices, slowly but surely making the 80 Plus Bronze certification fit only for low-range products.

There also are numerous 80 Plus Platinum certified products available and even a few 80 Plus Titanium certified units, such as the Corsair AX1500i, are making their appearance, albeit their ludicrous price tags. Meanwhile, the pricing of 80 Plus Platinum certified PSUs has become more reasonable, allowing the manufacturers to effectively implement the technology in their medium and high-end units. Today we have a couple more 80 Plus Platinum PSUs on our test bench.

Seasonic is a very well-known manufacturer of high quality PSUs, so they hardly need an introduction. Today, we are going to look at two of the new additions to their Platinum series, the Platinum SS-1050XP3 1050W and the Platinum SS-1200XP3 1200W. The name of the series is obviously linked with the 80 Plus Platinum efficiency certification of the units and it is their top-tier series, so these two new models also are the best consumer-grade PSUs that Seasonic currently offers. The 1050W and 1200W versions currently retail for $230 and $250 respectively, which are fairly reasonable prices considering their class and power output. How well can they perform though? We will find out in this review.

Platinum SS-1050XP3 - Power specifications ( Rated @ 50 °C )
AC INPUT 100 - 240 VAC, 50 - 60 Hz
RAIL +3.3V +5V +12V +5Vsb -12V
MAX OUTPUT 25A 25A 87A 3A 0.5A
125W 1044W 15W 6W
TOTAL 1050W

 

Platinum SS-1200XP3 - Power specifications ( Rated @ 50 °C )
AC INPUT 100 - 240 VAC, 50 - 60 Hz
RAIL +3.3V +5V +12V +5Vsb -12V
MAX OUTPUT 25A 25A 100A 3A 0.5A
125W 1200W 15W 6W
TOTAL 1200W

Packaging and bundle

We received both units in a long, very well designed cardboard box, with an elegant brushed metal color theme and reflective lettering. Inside the thick cardboard walls of the box, the unit is protected by Polyethylene foam pieces and is wrapped inside a synthetic cloth pouch, which can be repurposed. Information on the performance and the features of the unit can be found on the back of the box.

Both units share the same bundle, consisting of a well written manual, a case badge, four typical 3M mounting screws, a few cable ties, and six cable straps. We imagine that many enthusiasts would prefer black screws instead, but that is a minor misstep.

Both units share almost the same set of cables as well, with the exception that the 1200W version offers ten 6+2 pin PCI-E connectors instead of eight. The cables come supplied in a dual compartment nylon bag with the series logo printed on both sides. With the exception of the 24-pin ATX cable, all of the cables are flat, ribbon-like cables with no sleeving. The 24-pin ATX cables uses black wires as well, but they are individual wires and are covered with black sleeving.

The Seasonic Platinum SS-1050XP3 & SS-1200XP3 PSUs
Comments Locked

39 Comments

View All Comments

  • SodaAnt - Wednesday, September 3, 2014 - link

    I still tend to be slightly annoyed at the low efficiencies with high power PSUs at around 5% load or 50-75W. I noticed the article even said "Obviously using a 1200W PSU to drive a 60W load on a regular basis would be rather odd, so in most use cases the efficiency will be much higher." However, I don't really think that's true. Maybe that would have been the case 5 years ago, but now even monster rigs will easily use less than 100W when they are just idle at the desktop, which is a surprising amount of time. Further, there's quite a large subset of users that get a 1200W power supply, yet use it in a build with a single GPU and CPU, merely because they think they might upgrade later.

    In short, efficiencies at the low end should be higher.
  • LtGoonRush - Wednesday, September 3, 2014 - link

    76% efficiency at 5% load is EXTREMELY efficient, especially for a high-current power supply. There's a certain minimal overhead to power the electrical conversion hardware, and while it doesn't affect semi-passive models, the fan alone can account for 5% or more of efficiency losses at 50W draw. This overhead is also affected by the capacity of the power supply, as larger or parallel components increase overhead. The fact that a 1050W power supply is only wasting 12W of power at low load is quite respectable, and means that any improvements would have very minimal benefit.
  • SodaAnt - Wednesday, September 3, 2014 - link

    I think that wasting 12W of power at low load is actually quite a lot, mainly because the time scale is different. I'd say at least for my use case, 70% of the time is spent basically idling (internet browsing, writing a word doc, email, etc) or just not even using the computer at all. Especially for users who don't bother to turn off their computer, the 12W loss starts to add up pretty quick. I know its not easy to do, but I feel that because its not part of the spec for 80 plus, not very much effort is going into making improvements.
  • RaistlinZ - Wednesday, September 3, 2014 - link

    I think you expect too much. Anyone buying this is likely building a high-power overclocked rig, and wouldn't be spending much time at 5% power draw anyway. I also doubt the time, money, and effort into making PSU's 90%> efficient at 0-5% power draw is worth it from a manufacturing standpoint anyway.
  • fokka - Thursday, September 4, 2014 - link

    just because people are overclocking and gaming for a couple hours every day doesn't mean the close-to-idle times are negligable. people will still browse the web, write an email or watch a video or two.

    i'm not saying the inefficiencies at idle have to amount to a big loss compared to running a 1kw-pc at full load, but taken for itself it's still enough to power a complete low powered computer.

    i don't know about the engineering/physics side of things, but i'd say idle efficiency is still something manufacturers should look to improve.
  • Kutark - Sunday, September 14, 2014 - link

    The point is primarily that there is a minimum overhead that is needed to operate a power supply, and reducing that overhead is extremely difficult and in the end is not worth it. For example, if it takes say 12w of overhead, reducing that by 25% would basically put you at 9w. The return for the effort is simply not worth it (increased component costs, engineering/design costs, etc). Not many people would pay say a 10% price premium just to have the 5% load efficiency be 10% better so they can save basically save $6 a year in electricity costs.

    I've honestly never understood why people can't seem to pick their battles with these things. I always love when i would see people get into arguments here over a HDD that uses 8.2w instead of another one thats say 9.6w because its a 15% difference and thats massive! Well the reality is, its 1.4w. Now, in a corporate SAN environment where you might have say 500 of these drives in an array, yeah, 15% is a big deal. But to a home user who might have at most 2 of these drives in their computer, you're talking about $4/yr in electricity costs.

    Pick your battles.
  • dealcorn - Wednesday, September 3, 2014 - link

    If you use your over-clocking rig to browse the Internet you are wasting lots more than 12W. Get a petite, passively cooled Bay Trail desktop for browsing. Save the big rig for when you need the horsepower.
  • rarson - Sunday, September 21, 2014 - link

    Spend several hundred extra dollars to save a few bucks a year? That doesn't make any sense at all.
  • surt - Wednesday, September 3, 2014 - link

    Why does any power supply need to run a fan at 50w draw. Even if you're only 50% efficient at that load, you shouldn't need to actively cool 25w. If that's your overhead, just start the fan later.
  • Samus - Thursday, September 4, 2014 - link

    I want to chime in and agree with the OP here. Any PSU over 600W is going to be inherently inefficient at idle in many PC's.

    Below are my overclocked i5-4790 PC's individual power draw specifications taken with my Fluke multimeter, GW INSTEK GDS-122 oscilloscope using additive\deductive component elimination to calculate these measurements at idle within a reasonable margin of error using a PC Power & Cooling 750-QUAD 80-Plus PSU (which is really irrelevant since I am measuring current draw and using ohms law to convert into watts - the PSU has no bearing on the components individual power consumption.) However there is no reliable way to measure below 1 watt so the individual minimum component draw is such.

    Core i5 4690K @ 4500MHz 1.210v draws 12.8w at idle (FIVR reported via CoreTemp)
    2x8GB Crucial LPDDR3 @ 1600MHz 9-9-9 1.35v memory draws 3.2w at idle
    Samsung 840 Pro 256GB SSD 1.0w at idle
    Seagate 4TB 5900RPM 2.8w at idle
    WD 2TB 5200RPM (2.5") 1.7w at idle
    ASRock H87M-ITX measured via ATX connection 3.3+5.0+12.0 deduction 17.5w at idle
    EVGA nVidia Geforce 780Ti 3GB clocked 1025/7400 1.189v 22.8w at idle

    Total system draw before PSU efficiency loss is 62 watts. Since my PSU is only 75% efficient at 5-10% load, like most PSU's, my total system idle measured at the wall (with a somewhat accurate kill-a-watt) is 85 watts.

    However, I need a 750-watt PSU as my load power consumption can surprisingly eclipse 600-watts at full CPU + GPU load and I want to remain below the 80% load barrier where the PSU lifespan is shortened, temperatures and noise escalate and efficiency can REALLY take a dive.

    I think more attention needs to be taken with PSU efficiency at low idle state. There are various ways to do this, the most practical implementation being a dual stage power delivery circuit for different loads. Basically it would be a switching PSU inside a switching PSU, and it wouldn't be very expensive to produce because the first stage (lets say 0-100w) would be a very basic CLASS V, then there would be a voltage regulator and relay system that switches to the next stage with a supercap to isolate any voltage drop while switching.

    I'm surprised nobody has done this yet. Should I patent it?

Log in